Standard is the entry grade in the Greenwood film faced plywood range. It is built for formwork jobs that need a clean concrete finish for a limited number of pours: a 165 g/m² phenolic film on both faces, MUF glue with 12% melamine, an 8–12 hour boiling test and 4–8 reuses.
Knowing where the grade stops is as useful as knowing what it does. The most common complaint about entry-grade panels comes from using them on jobs that needed a higher grade.
Key specifications at a glance (TDS 08/2026)
- Film: phenolic film 165 g/m², both sides
- Glue: MUF, 12% melamine
- Boiling test: 8–12 h
- Expected reuse: 4–8 times (reference value)
- Thickness: 9–30 mm, tolerance ±0.5 mm
- Moisture content: ≤12%
Specification
Source: FOMEX Technical Data Sheet, 08/2026.
| Specification | Standard film faced plywood |
|---|---|
| Film | Phenolic film 165 g/m², both sides |
| Glue | MUF, 12% melamine |
| Boiling test | 8–12 h |
| Expected reuse | 4–8 times |
| Core | Eucalyptus, acacia or mixed hardwood (legally sourced plantation wood) |
| Plies | 5–13 depending on thickness |
| Thickness | 9–30 mm, tolerance ±0.5 mm |
| Sheet sizes | 1220 × 2440 mm, 1250 × 2500 mm or as requested |
| Moisture content | ≤12% |
| Edge sealing | Water-resistant paint |
| Packing | Pallet base or wooden blocks, PE wrap, steel strapping; custom labels on request |
Mechanical values
| Property | Test result | Requirement | Test method |
|---|---|---|---|
| Bending strength, length / width | 55.2 / 32.6 MPa | 50 / 30 MPa | TCVN 12446:2018 |
| Modulus of elasticity, length / width | 6465 / 4886 MPa | 6000 / 4500 MPa | TCVN 12446:2018 |
| Bonding strength | 0.74 MPa | 0.7 MPa | TCVN 12447:2018 |
| Moisture content | 9.4% | — | TCVN 11905:2017 |
Each result sits above the requirement in its row. Treat the figures as reference values from testing: on site, performance also depends on support spacing, load, exposure and handling.
Where Standard grade makes sense
- Short projects where each panel is used for up to about six pours.
- Walls, columns and footings on low-rise buildings.
- One-off or irregular formwork where panels are cut to shape and will not be reused many times anyway.
- Tenders where panels are written off at the end of the job and replaced for the next contract.
On these jobs, a higher grade would add specification the project never uses.
Where it does not
Standard grade is not the right choice for:
- High-rise or repetitive pours, where panels are cycled floor after floor. Look at Promax or Phenolic.
- Steam-cured or very wet work, which needs the longer boil-test performance of Promax (48 h) or Phenolic (72 h).
- Projects needing 8 or more uses from each panel. Premium is rated for 8–12.
If you are unsure, compare cost per pour rather than cost per sheet. Our guide to film faced plywood grades sets the four grades side by side.
Handling to reach the upper end of the reuse range
The 4–8 reuse range depends on how panels are treated on site. To reach the upper end:
- apply release agent evenly before each pour,
- clean panels soon after striking, without metal scrapers,
- seal every cut edge and drilled hole before first use,
- lift panels rather than dropping or dragging them,
- store panels flat, off the ground and covered between pours.
Panels leave the factory with edges sealed in water-resistant paint, so only site cuts need attention. How Many Times Can Film Faced Plywood Be Reused? covers the same factors across all four grades.
FAQ
How many times can Standard film faced plywood be reused?
The Greenwood data sheet gives 4–8 reuses for Standard as a reference value. Where a panel lands in that range depends on release agent, cleaning soon after striking, careful handling, sealed cut edges and dry, flat storage between pours. Rough handling can bring it below the range.
Is Standard grade suitable for slabs?
It can be used for slab formwork on short projects where each panel sees only a few pours. For repeated slab cycles on multi-story buildings, Premium at 8–12 reuses or Promax at 15–20 is the better fit, because the panel set has to survive the whole floor-by-floor programme.
What glue does Standard grade use?
Standard uses MUF glue with 12% melamine, the lowest melamine content in the Greenwood range. It passes an 8–12 hour boiling test. Higher grades raise the melamine content to 15–18% and 25%, or switch to phenolic glue, and their boil-test hours rise accordingly.
Can I order Standard grade with my own label?
Yes. Custom labels are available on request, alongside standard packing on a pallet base or wooden blocks with PE wrap and steel strapping. Send your label artwork and marking requirements with the order so they can be confirmed in writing before production starts.
Request the Standard grade data sheet
Tell us your thickness, sheet size and expected number of pours. Our team will send the Standard grade data sheet, or recommend a higher grade if your project needs it.
☎ +84 877 034 666 (WhatsApp)
Greenwood film faced plywood is a product line of FOMEX Global, part of FOMEX Group.